Köpguide för högfrekventa elektrodynamiska shakers

Köpguide för högfrekventa elektrodynamiska shakers



High Frequency  Electrodynamic shakers Purchasing Guide

Selecting the right high frequency vibration test machine is crucial to meet the specific needs and requirements of your industry. This purchasing guide will provide you with detailed information and specific data to help you make an informed decision. It takes into consideration industry pain points, hotspots, and international standards. Please find below the detailed guide in Engelska.

Nödvändiga testförhållanden

För att välja en lämplig elektrisk plattform är det viktigt att tillhandahålla följande information om dina vibrationstestförhållanden:
1. Frekvensområde (i Hertz, Hz) för vibrationsprovningen.
2. Magnitude of shaker test parameters such as acceleration (m/s² or g), displacement (mmp-p or p), velocity (m/s), or acceleration spectral density (PSD) values (g²/Hz or m²/s³).
3. Vibrationstestriktning: Oavsett om det är ett vertikalt test med en axel eller ett treaxligt (XYZ) test.
4. Mått (längd, bredd, höjd) och vikt på provexemplaret.
5. Provexemplarets vikt (i kilogram, kg).

Beräkning av val av elektrisk plattform
Baserat på de maximala dimensionerna och vikten på testexemplaret, välj en vertikal expansionsplattform.
The electric platform acts as the vibration source, and its working platform size is small, mainly used for fixture installation and expansion. Therefore, determine the size and weight of the expansion platform or fixture before the selection calculation. The main technical parameters of the vertical expansion platform are its dimensions, weight, and upper frequency limit. The maximum dimensions of the test specimen should be smaller than or equal to the expansion platform size, and the upper frequency limit of the vibration test should be smaller than or equal to the vertical expansion platform's upper frequency limit. Therefore, the dimensions and weight of the expansion platform can be determined based on the maximum dimensions and highest test frequency of the test specimen. The following data is for reference purposes only, as the specifications of the vertical platform or horizontal slide platform in different vibration equipment configurations may vary due to the different materials used.

Välj en horisontell glidplattform baserat på vibrationstestets riktning

Om vibrationstestet av testexemplaret endast krävs i vertikal riktning, är den vertikala expansionsplattformen tillräcklig. För allmänna vibrationstester som kräver treaxlig (axiell) vibration av provexemplaret, bör dock den fasta positionen under vibrationstestet simulera provexemplarets fasta position i dess arbets- eller transporttillstånd så mycket som möjligt.
Om det inte finns några specifika krav på installationsposition för testexemplaret i dess arbets- eller transporttillstånd, dvs. om ändring av testprovets tyngdpunkt genom att vända det inte påverkar dess prestanda, kan treaxlig vibration av testprovet uppnås genom att fixera vibrationsriktningen för den elektriska plattformen och ändra tyngdpunkten för testexemplaret. I det här fallet krävs endast en vertikal expansionsplattform. För stora testexemplar räcker det dock med en horisontell glidplattform på grund av den stora storleken på den elektriska plattform som krävs.
Om det finns specifika krav på installationsposition för testexemplaret i dess arbets- eller transporttillstånd, dvs. om en ändring av testprovets tyngdpunkt genom att vända det påverkar dess prestanda, måste vibrationsriktningen för den elektriska plattformen ändras för att uppnå treaxlig vibration av testprovet samtidigt som testprovets tyngdpunkt bibehålls oförändrad. I det här fallet krävs både en vertikal expansionsplattform och ett horisontellt vibrationsglidbord.
The technical specifications of the SC series horizontal slip table produced by ALITETSING——JOEO are provided below for reference. The selection process for the horizontal slide platform is similar to that of the vertical expansion platform. Note: The higher the upper frequency limit, the higher the required rigidity coefficient and the heavier the platform components. The calculation for the maximum acceleration in vibration testing is as follows:

Testförhållanden för sinusformade vibrationer är i allmänhet indelade i:
1) Constant Acceleration Swept Sine Test: f1--f2, Acceleration A1. In this test, the maximum acceleration within the frequency range from f1 to f2 is A1. The conversion formula for displacement D during swept frequency vibration is: D = A1×103/(2πf)2. Thus, the maximum displacement is D1MAX = A1×103/(2πf1)2.
2) Constant Velocity Swept Sine Test: f1--f2, Velocity V. The conversion formula between velocity and acceleration is: A = (2πf)V, where A is in m/s² and V is in m/s. Thus, the maximum acceleration is A2MAX = (2πf2)V. The conversion formula for displacement D during swept frequency vibration is: D = V×103/(2πf). Thus, the maximum displacement is D2MAX = V×103/(2πf1).
3) Constant Displacement Swept Sine Test: f1--f2, Displacement D. The conversion formula between displacement D and acceleration A is: A = (2πf)2D×10-3, where A is in m/s² and D is in mm. Thus, the maximum acceleration is A3MAX = (2πf)2D×10-3, and the maximum displacement is D.
4) Multipel Swept Sinustest med konstant acceleration och konstant förskjutning. Den maximala accelerationen för varje segment beräknas enligt ovan, och sedan väljs det maximala värdet från A1, A2MAX och A3MAX som den maximala accelerationen för testförhållandena. På samma sätt beräknas den maximala deplacementet från D1MAX, D2MAX och D, och det maximala värdet väljs som den maximala deplacementen för testförhållandena.

Beräkningen för den maximala accelerationen av slumpmässig vibration är som följer:
För slumpmässiga vibrationstestförhållanden med ett givet frekvensområde, spektraldensitetsvärde och ARMS (root mean square acceleration) är ARMS-värdet den maximala acceleration som krävs. Om ARMS-värdet inte anges måste det beräknas separat. Testförhållandena kan matas in i kontrollinstrumentet för slumpmässiga vibrationstester (programvara) för att beräkna ARMS-rotens medelvärde för kvadratisk acceleration och Drms vibrationsamplitud.

1. Calculate the acceleration value a based on the user's specified requirements. The test conditions are as follows:
20-80Hz, 3 dB/oct; 80-350Hz, 0.04g²/Hz; 350-2000Hz, -3 dB/oct.

2. Beräkningen är som följer:
1) För stigande spektrum (lutning N1 dB/okt):
Där m = N1/3.
 Then, F1 = 0.04×80[1-(20/80)²]/(1+1) = 1.5.
2) För platt spektrum:
   F2 = P(f3 - f2) = 0.04×(350-80) = 10.8.
3) För fallande spektrum (lutning -N2 dB/okt):
From F3 = 0.04×350[-ln(350/2000)] = 24.5.
The formula for a is a = √(F1 + F2 + F3).
Therefore, a = √(1.5 + 10.8 + 24.5) = 6.06g.

3. According to Newton's second law (F = ma), calculate the force F:
 F = (M1 + M2 + M3)×a,
 var:
 M1 - Vikt på den elektriska plattformens rörliga delar (kg).
 M2 - Vikt på den vertikala expansionsplattformen, den horisontella glidplattformen eller fixturen (kg).
 M3 - Maximal vikt på provexemplaret (kg).
 a - Maximum acceleration of the vibration test (m/s²).

Kraften F bör vara mindre än eller lika med den maximala sinusformade excitationskraften för den elektriska plattformen.
For random vibration, the force Frms is calculated as Frms = M×Arms and should be less than the rated random excitation force of the electric platform.

4. Bekräfta att den elektriska plattformens maximala förskjutning är större än den maximala förskjutningen under provningsförhållandena. För slumpmässig vibration bör det kvadratiska amplitud-Drms som beräknas av datorn vara mindre än en tredjedel av den elektriska plattformens nominella amplitud.

5. Välj ett sinuskontrollinstrument eller ett slumpmässigt vibrationskontrollinstrument baserat på de specificerade testförhållandena. Om det finns parametrar för slumpmässig vibration måste ett slumpmässigt vibrationskontrollinstrument väljas.

Slutsats

När du väljer en högfrekvent vibrationstestare är det avgörande att ta hänsyn till de specifika kraven i din bransch, inklusive testförhållanden, beräkning av val av elektrisk plattform, kraftberäkning och behovet av sinus- eller slumpmässig vibrationskontroll. Genom att följa denna köpguide och ta hänsyn till de detaljerade specifikationerna och kraven kan du välja den mest lämpliga högfrekventa vibrationstestaren för din bransch.

Observera att den här guiden ger detaljerad information baserad på branschens behov, smärtpunkter och internationella standarder. Det rekommenderas att studera produktmanualerna och relevanta specifikationer för att säkerställa att den inköpta utrustningen uppfyller dina specifika krav innan den faktiskt används.

Kontakta oss